Overview

James T. Dobbins III, PhD., FAAPM
Associate Vice Provost
Director, Office of Duke Kunshan University Programs
Professor of Radiology, Biomedical Engineering, and Physics
Chair, Education Council, American Association of Physicists in Medicine
Co-founder, Society of Directors of Academic Medical Physics Programs, Inc.

I serve in senior university administration as Associate Vice Provost for DKU Programs.  In this role I oversee the academic and programmatic efforts at Duke for the establishment of the graduate and undergraduate programs at Duke Kunshan University -- Duke's joint venture university in Kunshan, China.

My research career has focused on the application of physics to medicine.  I undertake projects that range from theoretical/mathematical projects, to invention of new imaging devices, to clinical trials and implementation of new imaging modalities.  Several research projects in my lab have resulted in commercial products that are now in use in hundreds of hospitals around the world.

I also have a passion for leadership and education.   I was the founding Director of the Medical Physics Graduate Program at Duke, which includes over 50 faculty and 50 MS and PhD students in diagnostic imaging physics, radiation oncology physics, nuclear medicine physics, and medical health physics.  I co-founded the Society of Directors of Academic Medical Physics Programs, Inc, which works to strengthen medical physics education worldwide.  And I currently serve as Chair of the Education Council for the American Association of Physics in Medicine, and through this work influence major educational directions for our field.

Whether in biomedical research, education, or university leadership, the goal of my career has been to enhance the common good in our globally connected community.

Education & Training

  • Ph.D., University of Wisconsin at Madison 1985

  • M.S., University of Wisconsin at Madison 1983

  • B.S., University of North Carolina at Chapel Hill 1978

Fellowships, Supported Research, & Other Grants

GE Healthcare VolumeRAD lung nodule detection study awarded by GE Healthcare (2009 to 2010)

Digital radiography research agreement with General Electric awarded by General Electric (2000 to 2006)

Samei, Ehsan, et al. “A framework for optimising the radiographic technique in digital X-ray imaging..” Radiat Prot Dosimetry, vol. 114, no. 1–3, 2005, pp. 220–29. Pubmed, doi:10.1093/rpd/nch562. Full Text

Samei, Ehsan, et al. “Fundamental imaging characteristics of a slot-scan digital chest radiographic system..” Med Phys, vol. 31, no. 9, Sept. 2004, pp. 2687–98. Pubmed, doi:10.1118/1.1783531. Full Text

Duryea, J., et al. “Digital tomosynthesis rendering of joint margins for arthritis assessment.” Proceedings of Spie  the International Society for Optical Engineering, vol. 5368, no. 1, July 2004, pp. 12–18. Scopus, doi:10.1117/12.535850. Full Text

Dobbins, James T., and Devon J. Godfrey. “Digital x-ray tomosynthesis: current state of the art and clinical potential..” Phys Med Biol, vol. 48, no. 19, Oct. 2003, pp. R65-106. Pubmed, doi:10.1088/0031-9155/48/19/r01. Full Text

Godfrey, D. J., et al. “Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS).” Proceedings of Spie  the International Society for Optical Engineering, vol. 5030 I, Sept. 2003, pp. 379–90. Scopus, doi:10.1117/12.480352. Full Text

Duryea, J., et al. “Digital tomosynthesis of hand joints for arthritis assessment..” Med Phys, vol. 30, no. 3, Mar. 2003, pp. 325–33. Pubmed, doi:10.1118/1.1543573. Full Text

Warp, Richard J., and James T. Dobbins. “Quantitative evaluation of noise reduction strategies in dual-energy imaging..” Med Phys, vol. 30, no. 2, Feb. 2003, pp. 190–98. Pubmed, doi:10.1118/1.1538232. Full Text

Maidment, A. D. A., et al. “Standardization of NPS measurement: Interim report of AAPM TG16.” Proceedings of Spie  the International Society for Optical Engineering, vol. 5030 I, Jan. 2003, pp. 523–32. Scopus, doi:10.1117/12.480451. Full Text

Dobbins, James T., et al. “Chest radiography: optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector..” Radiology, vol. 226, no. 1, Jan. 2003, pp. 221–30. Pubmed, doi:10.1148/radiol.2261012023. Full Text

Samei, E., et al. “Optimum radiographic technique for chest radiography using a flat-panel digital detector.” Radiology, vol. 225, RADIOLOGICAL SOC NORTH AMERICA, Nov. 2002, pp. 642–43.

Pages